Short Circuit Fault Current
ARCAD INC.BusinessGoogle PlayIn-app purchasesShort Circuit Fault Current revenue and downloads, last 30 days
How we got this (12 inputs)
- signals
- Play installs ÷ age; lifetime→current drift ×/÷4.12 (135278 measured Play counter deltas)
- spread
- measured on downloads ground truth (downloads ground truth: 48 App Store milestones, 33 platform splits, 13 drift points)
- installs
- 16920
- age days
- 4180
- bound
- at most the lifetime installs counter (16920) over 30 days: the listing is 4180 days old, so its last 30 days cannot hold more installs than it ever had
- range scale
- ×0.88 (coverage scale on 9 ground-truth rows; publication is decided before it)
- likelyLow
- 96
- likelyHigh
- 360
- confidence
- medium
- observed days (of 30)
- 1
- measured days
- 0
- scaling
- observed days, scaled to 30
As of Nov 21, 2026.
How we got this (12 inputs)
- method
- installs in the window (all active on install day) + earlier installers active in the month (published retention ÷ the category's DAU/MAU stickiness) + the retained base of installers older than two years
- downloads per day
- 6.2 (1.77 to 21.63, the published worldwide figure)
- retention
- day 1 / 7 / 30: 17.88% / 4.93% / 1.85% (Android benchmark × 0.88 for the category; AppsFlyer Q3 2024 day-1/7/30 retention, via getstream.io/blog/app-retention-guide (read 2026-11-16); category: OneSignal 2024 day-30 retention by category, via getstream.io/blog/app-retention-guide (read 2026-11-16))
- active days per install
- 4.84 over 730 days (age 4180 days; the curve is used to 730)
- stickiness
- 17.5% DAU/MAU, Productivity & Tools median (MWM DAU/MAU medians, US iOS, May 2026 (mwm.ai/glossary/dau-mau, read 2026-11-16))
- parts
- window installs 186 (the published 30-day downloads), earlier installers 110, retained base 516
- retained base
- 12395 installers older than 730 days (lifetime from the listing's Play installs counter) × 4.16% active in a month (between 1.23%, the benchmark curve held flat, and 14.1%, median disclosed MAU ÷ lifetime installs of Duolingo, Snapchat and Grindr (company filings, data/ground-truth-active-users.csv; chosen on these rows, scored leave-one-product-out)); range ×/÷2 past each (widened after the leave-one-product-out check)
- spread
- downloads ×/÷3.5, retention ×/÷3, tail ×/÷1.56, stickiness ×/÷1.8, retained base ×/÷6.78 (assumptions; not fitted)
- chart persistence (recorded, not used)
- 0 day(s) on a chart in the window; fewer than 7 live days exist
- tier
- modelled: retention and stickiness are published benchmarks, not measured on this listing
- confidence
- low
- rough
- order of magnitude
As of Nov 21, 2026.
Daily active users
Modelled from this app's downloads and a published retention curve for its store and category, not measured. Read it as an order of magnitude.
History
Daily readings as we observed them, last 30 days worldwide. Free shows the last 30 days.
One reading so far: history starts Nov 21, 2026, and a trend line appears after the next daily reading.
Installs, Play counter
Observed by us since Nov 21, 2026.
Monthly history: we have found no public-archive copy of this store page from the last 12 months, so monthly readings start with our own in Nov 2026.
Create a free account to save apps; Pro shows full history.
Chart positions
Where this app ranks on the top free, paid and grossing charts we capture.
Search terms
No search terms read for this app yet. Terms are read from its title and the searches it shows up in, and appear here once ranked.
In-app purchases
Google Play shows one in-app price range per storefront, not each product's price. The range over time, as the store published it:
United States, USD
- $65.06 per itemNov 23, 2026 to now
Prices
In-app purchase ladder, price changes and paywall terms
No itemised in-app prices yet. Google Play publishes only the price range shown above, not each product; the individual products and their prices have not been read.
Ratings and reviews
Rating distribution
No rating distribution read yet.
Recent reviews
Marketing
Paid ads, organic videos and onboarding captured for this app.
Paid ads
No Meta, Google or TikTok ads tied to this app yet. We check the public ad libraries daily.
Onboarding
No store screenshots, web funnel or in-app recording captured for this app yet.
Change history
Versions, price changes, rank jumps and listing edits, as we observed them.
Details
- Developer
- ARCAD INC., 2 apps
- Package
- com.arcadvisor.shortcircuitanalytic
- Category
- Business
- Price
- Free
- Released
- Jun 12, 2015
- Updated
- Jan 24, 2024
- Version
- 1.0.18
- Size
- -
- Content rating
- Everyone
- Website
- arcadvisor.com
- Contact email
- apps@arcadvisor.com
- Privacy policy
- arcadvisor.com/terms-conditions
- Languages
- Not available
- Charted in
- United States
- First seen
- Nov 21, 2026
- Listing read
- Nov 23, 2026
Show store descriptionShow less
Short Circuit Analytic mobile app performs available short circuit fault current calculations in three-phase radial power system you are working with. The app takes into consideration all of the key electrical parameters of power distribution system including power supply, cables, transformers, generators and motors. The source can be set as a transformer supply or a busbar with a specified short circuit level. If a transformer source is used, the short circuit level on the primary side can be set to infinity by setting the data field blank. Add components one by one to build up a single line diagram. The components can be cables, transformers, ligting loads, electrical devices, motors and generators. After a component has been added, its data can be edited by tapping the component when displayed on the screen. Tap on 'Run Analysis' button to calculate available 3-phase and phase-to-phase short circuit current values and fault X/R ratio at each busbar. Additional information about SCA V1.0 mobile and the comprehensive method for short circuit analysis Simple point-to-point short circuit fault current calculations are carried out using Ohm's law and equipment resistance values. To determine fault current at various locations within power system, the system characteristics such as available short circuit value at service entrance, line voltage, transformer KVA rating and percent impedance, conductor characteristics are utilized. The calculations become more complicated when resistance values are replaced with an impedance values. For instance, transformer ratio of reactance to resistance (X/R) is used along with transformer percent impedance to determine X and R values on a per unit bases. Similarly, the impedance for conductors within the electrical system are also broken down into X and R components of the impedance. The peak asymmetric fault current is also determined by X/R ratio. The total asymmetric current is a measure of the total DC component and the symmetrical component. The asymmetrical component decays with time and will cause the first cycle of a fault current to be larger in magnitude than the steady-state fault current. Also, the decay of the DC component depends on the X/R ratio of the circuit between the source and the fault. Knowing the fault X/R ratio is essential when selecting electrical and protection equipment. For example, all low-voltage protective devices are tested at predetermined X/R ratios. If the calculated X/R ratio at any given point in the electrical distribution system exceeds the tested X/R ratio of the overcurrent protective device, alternate gear with adequate X/R rating should be considered or the device effective rating must be reduced. Features and Capabilities: 1. Calculate 3-phase, phase-to-phase short circuit currents at each bus within your power distribution system 2. Determine maximum available short circuit current, the amount of maximum upstream short circuit current and the minimum available short circuit current contributed by one source only. Both the available short circuit current (ASCC) and the part of ASCC through protection device current values are required for comprehensive arc flash hazard analysis using NFPA 70E and IEEE 1584 methods 3. Compute contributions from generators and motors 4. Add North American wire gauge cables as well as international cables 5. Perform comprehensive short circuit analysis by taking into account both active and reactive parts of equipment impedance 6. Determine fault X/R ratio at each bus 7. Save, rename, duplicate single-line diagrams and equipment data 8. Export, import one-line diagrams and all the equipment data for easy sharing 9. Send calculation results and captured single-line diagrams by email
More like this
- Top Business on Google Play by estimated revenue
- Short Circuit Fault Current alternatives
- Short Circuit Fault Current vs Contact Organizer
- Short Circuit Fault Current vs iVerify Basic
- All top charts and categories